CAST IMAGING - V3 - Analysis - Java - jeeiecmd failed to start. Error code = 1

User reported failures during Java analysis in Imaging V3. 

From the jeeiecmd.log file, the following error message can be seen

[INFO] Loading MetaModel from cache.
[INFO] loading JEE Objects
[ERROR] Unexpected error in IECmd executable: bad allocation
[ERROR] jeeiecmd failed to start. Error code = 1
[ERROR] Error when launching jeeiecmd

 

Solution

  1. Check if UNC paths are used. If used map the network drives instead of using a UNC path (Universal Naming Convention path).
  2. Upgrade to the latest version of JEE analyzer.
  3. Run the analysis with additional memory

 