User got a White label Error Page with “(type=Internal Server Error, status=500) Unable to resolve the Configuration with the provided Issuer” after logging into the CAST Imaging application. The issue occurs immediately after authentication when attempting to access the application.
There was an unexpected error (type=Internal Server Error, status=500).
Unable to resolve the Configuration with the provided Issuer
Anything that prevents Imaging from fetching or validating the issuer metadata can trigger this error.
Solution
Check the admin centre field of the application.yml files of both the gateway and the auth service. If local host is mentioned in it change it to Fully Qualified Domain Name instead of hostname.
Related Articles
CAST IMAGING – V3 – SSO - Login - Internal Server Error HTTP 500 - HttpHostConnectException
Resources
CAST Imaging v3 Product Documentation
CAST Imaging Troubleshooting Guides
Additional Resources
CAST Highlight Product Documentation
CAST Highlight Troubleshooting Guides
Ticket
57520